One unit supply floor heating and hot water, easy solution for integrated heating demand.
Anti-freezing technologies to overcome ultra-low temperature environment. Adopt unique air jet enthalpy compression technology, add economy, chassis heating belt, crankshaft heating belt, "dual core power" rapid heating.
Adopting the international brand Copeland EVI ZW series compressor, it is suitable for running in ultra-low temperature environment. Ensure the heating efficiency ratio in ultra-low temperature environment.
Apply Sanhua new generation electronic expansion valve to relize automatic temperature adjustment in the cryogenic environment; no only improve the efficiency but also protect the life time of comressor effectively,.
No need to be on duty, automation, automatic water supply, heating and power off. Over 100 meters long distance control, automatic fault diagnosis, power off memory functions etc.
TECHNICAL DATA | RS-36DV1 | RS-48DV1 | RS-72DV1 | RS-96DV1 | ||
Heating | Heating capacity | kw | 30 | 39 | 60 | 78 |
Input power | kw | 7.5 | 9.7 | 15 | 19.4 | |
COP | w/w | 4 | 4.02 | 8 | 4.02 | |
DHW | Heating capacity | kw | 30 | 39 | 60 | 78 |
Input power | kw | 8.1 | 10.5 | 16.2 | 21 | |
COP | w/w | 3.7 | 3.71 | 3.7 | 3.71 | |
Power supply | V/Ph/Hz | ~380V/3/50Hz | ||||
Max.Input power | kw | 14.3 | 19.7 | 28.6 | 39.4 | |
Max.Current | A | 25.5 | 35.3 | 51 | 70.6 | |
Max.Outlet water temperature(without heater) | ℃ | 55 | ||||
Working temperature range | ℃ | -60 | ||||
Refrigerant | Type | R407C | R410A | R407C | R410A | |
Compressor | Quantity | 1 | 1 | 2 | 2 | |
Brand 1# | Copeland | Copeland | Copeland | Copeland | ||
Evaporater Heat exchanger | Type | High efficiency hydrophilic fin-tube | ||||
Economic Heat exchanger | Type | SUS 316 Stainless steel plate | ||||
Water pump | Brand | / | ||||
EEV | Type | SANHUA | ||||
Fan motor | Brand | AIRFLOW | ||||
Quantity | 1 | 2 | 2 | 4 | ||
Power input(w) | 1100 | 850 | 1100 | 850 | ||
rpm | 900 | 1350 | 900 | 1350 | ||
Fan Size | mm | 710 | 630 | 710 | 630 | |
Heat exchanger | Type | Tube in shell heat exchanger | ||||
Water flow | m/h | 5.2 | 6.7 | 10.5 | 13.4 | |
Inlet/outlet pipe | inch(mm) | DN40 | DN50 | DN40*2 | DN50*2 | |
Net Dimensions | mm | 1100x950x1865 | 1680x950x1865 | 1100x1900x1865 | 1680x1900x1865 | |
Net weight | kg | 380 | 440 | 760 | 880 | |
Noise level | dB(A) | ≤65 | ≤65 | ≤65 | ≤65 |
NOTES:
Capacities and power inputs based on the following conditions:
- Heating: Water Inlet/Outlet temperature 30℃/35℃. Outdoor air dry bulb/wet bulb temperature 7℃/6℃
- Domestic Hot Water: Water temperature in the tank 40℃. Outdoor air dry bulb/wet bulb temperature 7℃/6℃
Energy Saving
Expenses comparison- 1 ton water to heat from 15℃ to 55℃
Name | Energy Source | Energy Price | Average Expenses |
Solar water heater and electronic auxiliary (Calculated for 90-120 days electronic auxiliary | Solar energy and electricity | Electricity 0.8RMB/Degree Free solar energy | 13RMB/Ton |
Diesel oil boiler | Diesel oil | 4.9RMB/Kg | 32RMB/Ton |
Fuel gas water heater | Gas | 6.0RMB/Kg | 39rmb/Ton |
Electrical water heater | Electricity | 0.8RMB/degree Free solar energy | 9RMB/Ton |
Environmental Protection
Heat comes from air, no exhaust gas produced. Protect our environment is social morality.
According to the study indicated that, for each unit of electricity ,the consumption of fossil material to about 0.67Kg of carbon dioxide release. China’s average temperature and a five-person households use hot water sa an example, one-year results of the air to water heater, carbon dioxide emissions can be reduced to 500kg, And save a few thousand dollars per year of liquefied gas and electricity costs .
Easy Install
Remark:1..Before starting the main unit, it is necessary to ensure that there is sufficient water in the transition tank to operate.
2.When power off in winter, water must be drained out rom the pipes to revent the cracking of the water pipes
Heodoor engineering machine installation diagram
One unit supply floor heating and hot water, easy solution for integrated heating demand.
Anti-freezing technologies to overcome ultra-low temperature environment. Adopt unique air jet enthalpy compression technology, add economy, chassis heating belt, crankshaft heating belt, "dual core power" rapid heating.
Adopting the international brand Copeland EVI ZW series compressor, it is suitable for running in ultra-low temperature environment. Ensure the heating efficiency ratio in ultra-low temperature environment.
Apply Sanhua new generation electronic expansion valve to relize automatic temperature adjustment in the cryogenic environment; no only improve the efficiency but also protect the life time of comressor effectively,.
No need to be on duty, automation, automatic water supply, heating and power off. Over 100 meters long distance control, automatic fault diagnosis, power off memory functions etc.
TECHNICAL DATA | RS-36DV1 | RS-48DV1 | RS-72DV1 | RS-96DV1 | ||
Heating | Heating capacity | kw | 30 | 39 | 60 | 78 |
Input power | kw | 7.5 | 9.7 | 15 | 19.4 | |
COP | w/w | 4 | 4.02 | 8 | 4.02 | |
DHW | Heating capacity | kw | 30 | 39 | 60 | 78 |
Input power | kw | 8.1 | 10.5 | 16.2 | 21 | |
COP | w/w | 3.7 | 3.71 | 3.7 | 3.71 | |
Power supply | V/Ph/Hz | ~380V/3/50Hz | ||||
Max.Input power | kw | 14.3 | 19.7 | 28.6 | 39.4 | |
Max.Current | A | 25.5 | 35.3 | 51 | 70.6 | |
Max.Outlet water temperature(without heater) | ℃ | 55 | ||||
Working temperature range | ℃ | -60 | ||||
Refrigerant | Type | R407C | R410A | R407C | R410A | |
Compressor | Quantity | 1 | 1 | 2 | 2 | |
Brand 1# | Copeland | Copeland | Copeland | Copeland | ||
Evaporater Heat exchanger | Type | High efficiency hydrophilic fin-tube | ||||
Economic Heat exchanger | Type | SUS 316 Stainless steel plate | ||||
Water pump | Brand | / | ||||
EEV | Type | SANHUA | ||||
Fan motor | Brand | AIRFLOW | ||||
Quantity | 1 | 2 | 2 | 4 | ||
Power input(w) | 1100 | 850 | 1100 | 850 | ||
rpm | 900 | 1350 | 900 | 1350 | ||
Fan Size | mm | 710 | 630 | 710 | 630 | |
Heat exchanger | Type | Tube in shell heat exchanger | ||||
Water flow | m/h | 5.2 | 6.7 | 10.5 | 13.4 | |
Inlet/outlet pipe | inch(mm) | DN40 | DN50 | DN40*2 | DN50*2 | |
Net Dimensions | mm | 1100x950x1865 | 1680x950x1865 | 1100x1900x1865 | 1680x1900x1865 | |
Net weight | kg | 380 | 440 | 760 | 880 | |
Noise level | dB(A) | ≤65 | ≤65 | ≤65 | ≤65 |
NOTES:
Capacities and power inputs based on the following conditions:
- Heating: Water Inlet/Outlet temperature 30℃/35℃. Outdoor air dry bulb/wet bulb temperature 7℃/6℃
- Domestic Hot Water: Water temperature in the tank 40℃. Outdoor air dry bulb/wet bulb temperature 7℃/6℃
Energy Saving
Expenses comparison- 1 ton water to heat from 15℃ to 55℃
Name | Energy Source | Energy Price | Average Expenses |
Solar water heater and electronic auxiliary (Calculated for 90-120 days electronic auxiliary | Solar energy and electricity | Electricity 0.8RMB/Degree Free solar energy | 13RMB/Ton |
Diesel oil boiler | Diesel oil | 4.9RMB/Kg | 32RMB/Ton |
Fuel gas water heater | Gas | 6.0RMB/Kg | 39rmb/Ton |
Electrical water heater | Electricity | 0.8RMB/degree Free solar energy | 9RMB/Ton |
Environmental Protection
Heat comes from air, no exhaust gas produced. Protect our environment is social morality.
According to the study indicated that, for each unit of electricity ,the consumption of fossil material to about 0.67Kg of carbon dioxide release. China’s average temperature and a five-person households use hot water sa an example, one-year results of the air to water heater, carbon dioxide emissions can be reduced to 500kg, And save a few thousand dollars per year of liquefied gas and electricity costs .
Easy Install
Remark:1..Before starting the main unit, it is necessary to ensure that there is sufficient water in the transition tank to operate.
2.When power off in winter, water must be drained out rom the pipes to revent the cracking of the water pipes
Heodoor engineering machine installation diagram